RTU5024Verificado
RTU5015
por King Pigeon
FabricanteKing Pigeon
ProtocoloRTU5024
Contraseña predeterminada1234
Usuarios máximos64
Relés1
AlimentaciónDC 9-36V
Tipo de SIMStandard SIM
Capacidad del relé3A / 240VAC
Temperatura de funcionamiento-10 to +60 C
Dimensiones88 x 62 x 25 mm
Comandos más usados
Ver todos →Initialize (REQUIRED first step)
Register the module's SIM card number. This is the FIRST command you must send. Use 00 prefix instead of +.
Sintaxis:
{pwd}TEL{moduleSIM}#Ejemplo:
1234TEL00861351015#Sync clock
Set the module's internal clock. Required for time-limited users to work correctly.
Sintaxis:
{pwd}T{YYMMDDHHmm}#Ejemplo:
1234T2603291530#Change password
Change device password to new 4-digit password.
Sintaxis:
{pwd}P{newpwd}Ejemplo:
1234P6666Add permanent user
Add authorized user to slot (001-200). Always allowed to call and control.
Sintaxis:
{pwd}A{slot}#{phone}#Ejemplo:
1234A003#123456#Add time-limited user
Add user with access limited to a date/time range. Clock must be synced first.
Sintaxis:
{pwd}A{slot}#{phone}#{startYYMMDDHHmm}#{endYYMMDDHHmm}#Ejemplo:
1234A016#123456#1502050800#1502051000#Olvídate de los comandos SMS
GateOpener traduce todos estos comandos a una interfaz clara. Añade usuarios, configura ajustes y abre tu puerta — sin recordar un solo código.
Descargar GateOpener